TEMPERATURE GAUGES ....
1) GENERAL PURPOSE DIAL TYPE THERMOMETERS
"OSMADIAL
/ SCIECON" Mercury in Steel General
Purpose temperature gauges are basically designed
to measure the temperature, which operate on the principal
of change of shape of boudens tube on account of internal
pressure variation due to change in volume of mercury
inside the sensor probe caused by the temperature.
 |
Case |
: |
Heavy duty die cast aluminium stoved
enamelled Black finished IP-55 weather proof surface
mounting case |
| Dial Size |
: |
100mm Ø, 150mm Ø |
| Range |
: |
- 30 to upto + 600°C |
| Capillary |
: |
Red PVC/Copper/S.S covered flexible
Capillary upto 30 mtr can be provided. |
| Bulb/Stem |
: |
M.S / S.S Bulb/Stem 1/2” O.D
x 10” Total Length or as required. |
| Connection |
: |
1/2”/3/4” BSP/NPT (M)/(F)
adjustable connection. |
Optional
:
The same can be provided with Stem type, Direct
Vertical Mounting. Electrical Contacts can
be Provided if required. |
 |
|
|
2) COMPENSATED SYSTEM TYPE TEMPERATURE GAUGES
"OSMADIAL
/ SCIECON", Mercury Filled FULLY
COMPENSATION TYPE dial thermometers is used in
Chemical reactors of Chemical, Dyestuff, Sugar, Food &
Fertilizer Industries.
The object of the thermometer is to detect changes of
the temperature at the bulb. There is however, the possibility
of error caused by variation of temperature along the
tubing or at the pressure spring itself. In long system
where the length of the capillary or tubing is more then
2 mtr, the volume of the tubing may be great enough to
allow temperature changes along the tubing.
Now, Fully Compensated systems employ a second pressure
spring and tubing. By means of linkages, the motion of
the compensating pressure is made equal and opposite to
the motion of the primary pressure spring. If the temperature
along the primary tubings varies, causing expansion of
the primary spring, the expansion of the compensating
spring due to the same variation acts to cancel out the
resulting motion of the indicating mechanism and thereby
showing the actual mechanism.
| Case |
: |
Heavy duty die cast aluminium stoved
enamelled Black finished IP-55 weather proof surface
mounting case. |
Model
No. : 1130
|
| Dial size |
: |
150mm |
| Range |
: |
-30° c to upto +600°C. |
| Capillary |
: |
Red PVC/Copper/S.S covered TWIN
flexible Capillary for Compensation, upto
30 mtr can be provided. |
| Bulb/Stem |
: |
M.S / S.S Bulb/Stem 1/2” O.D
x 10” Total Length. |
| Connection |
: |
½", ¾"
BSP/NPT (M) / (F) connection. |
| Direct
vertical mounting type can be provided.
|
|
3) ANTI-VIBRATION TYPE EXHAUST TEMPERATURE
INDICATORS
"OSMADIAL / SCIECON",
Mercury in Steel Anti Vibration
type dial thermometesr suitable for measuring Diesel
Exhaust Temperature in Diesel Generator Set, Navy Ships,
Submarines etc where there is lot of vibration.
Model
No. : Ex-- 1028  |
Case |
: |
Heavy duty
die cast aluminium stoved enamelled Black finished
IP-55 weather proof direct Vertical Mounting case. |
| Dial
size |
: |
100mm
Ø, 150mmØ |
| Range |
: |
-30°c to upto +600°C. |
| Bulb/Stem |
: |
M.S / S.S, 1/2”
OD x 300mm total Length or as required, alongwith
Anti-Vibration spring provided at Bottom entry of
the case. |
| Connection |
: |
½", ¾"
BSP/NPT (M) / (F) adjustable
connection. |
| Zero Adjust |
: |
Provided with External
Zero Adjustment. |
| |
|
|
| Optional
: |
|
The same can be provided
with Gycerine filled. |
| |
|
|
| |
|
|
| |
|
|
|
|
|